Installation consists of four steps, Unpacking the Equipment, Message Center mounting, Connections, and Software setup. Be sure to read and understand all of the instructions before installing the equipment. Consult the "installer's trouble shooting guide" following this section for verifications each step has been installed and is working correctly.

  • Inspect the shipping container for damage. If any damage can be seen, contact the carrier immediately.
  • Carefully remove all equipment from its packing carton. Do not pry against the message center in any way.
  • Nevco strongly encourages you to check local codes before beginning the installation. You may wish to contact a local architect, contractor, or sign installer for assistance. Your Nevco Sales Representative may be able to assist you in finding professional installers who are familiar with this type of equipment.
  • Always use good mechanical practices when mounting the message center.
  • Use plated fastening devices to prevent rust or corrosion.
  • Mount the optional photocell out of direct sunlight to avoid an elevated reading.
  • Mount the two wireless devices (if present) in clear line of sight with each other.
  • For indoor installations, install angle iron on wall or other structure prior to attaching the message center. Angle iron and attachments (bolts, washers, etc.) are not included. See installation drawings for approximate distance between angle iron supports.
  • For outdoor installations, install tubing laterals on columns prior to installing the message center. Laterals should be welded or bolted to steel columns. Laterals and attachments (bolts, washers, nuts, etc.) are not included. See installation drawings for approximate distance between lateral supports. Brackets on message centers can be welded or bolted to the laterals.
  • Each message center comes with 2 lifting points on the top of the unit. When using the lifting points, make sure cables are vertical and not putting an undue horizontal force on the lifting points. Use of a spreader bar is recommended when using the lifting points.
  • For multi-section message centers, make sure the cabinets and supports line up vertically and horizontally. Cabinets should be installed as tight as possible to each other. Where the sections join together, a bracket shall be installed at the top and bottom. Half of the bracket should support each section.

Your Message Center was designed so that it can be mounted in a variety of ways. Please examine the installation drawings to determine the best mounting method for your location. Access to all internal components is through the front, accessibility to the rear of the cabinet is NOT necessary.

Each message center, whether it is made up of two cabinets end to end, or two cabinets back to back (double sided), or a single cabinet, requires that power and signal be supplied to each cabinet by the installer. All internal connections have been completed and tested at the factory.

Both power and data should enter each message center cabinet at its lower left corner as viewed from the front. An access panel is provided for these connections. The "signal in" conduit attaches to the panel and a junction box is mounted on the panel for power connections. Similar access panels are installed on the back and bottom of the cabinet. All three panels are interchangeable so that the one with the junction box can be located in the most favorable position. The panel with the junction box can be moved to either of the other locations without disconnecting any cables inside the message center.

NOTE
NOTE: Be sure to reattach all panels so as to maintain a weather tight seal.

The optional light sensor should be mounted near this location and needs to be connected to a cable inside the message center behind the access panel.

At the lower right corner of the message center as viewed from the front is a similar arrangement for the "signal out" if needed. Used for side 2 of a two sided message center, and message centers made up of two cabinets mounted end to end.

NOTE
NOTE: Please see installation drawings for more details.

Each message center requires that power and signal be supplied to each cabinet by the installer. All internal connections have been completed and tested at the factory. Both power and data should enter each message center cabinet at its upper left corner as viewed from the front. A 15' Nema 5-15P to C13 power cable is included with the message center.

NOTE
NOTE: Please see installation drawings for more details.
  • Refer to installation prints for illustration of electrical connections.
WARNING
WARNING: This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign.
  • Consult table 1 for power requirements for your message center model. Provide for a 30% safety factor to guard against tripping of the circuit breaker under low line conditions.
  • Be sure to include any lighted signs, and account for double sided displays when sizing the supply wiring necessary to support the circuit load.
  • A disconnect switch should be lockable or within sight of the sign per NEC article 600.

Table 1 — Power Requirements

Cabinet DimensionsCurrent @120VACurrent @240VA
16mm Color Outdoor3x863
3x1094.5
3x1211.35.7
3x16 Left7.53.8
3x16 Right7.53.8
4x8105
4x10126
4x12 Left73.5
4x12 Right84
4x16 Left105
4x16 Right105
6mm Color Indoor3x85.82.9
3x1073.5
4x87.83.9
4x109.34.7
  • If rigid EMT is used, use ¾" rain-tight conduit fittings to avoid cutting the ends off included pre-made cables.
WARNING
WARNING: Take care not to reverse the connections on the POE adapter as this will damage the controller. Refer to installation print and color coding for details.
NOTE
NOTE: Mobile Device and Customer Wireless Access Point are only required for Live Control of the display.

Once the message center is powered up after a minute or so it should display configuration status information similar to Figure 1- Display Status Information Screen. This will remain on until the message center has internet connection and the end user has completed setup in their Nevco ONE account.

#16316457
Playlists: (NONE)
Display: 150x45 - CUSTOM
10:13:57 GMT-0500 (Central Daylight Time)
Software: UNKNOWN
Cloud Connect: NO

Figure 1- Display Status Information Screen

It may be necessary to configure a static IP address depending upon the network requirements of the customer. The following instructions will show how to set the IP address and identify MAC address if needed for the IT administrator to open up access to reach the internet through a network Firewall.

  1. Download and install the Nevco ONE Controller App from the app store to your iOS or Android phone.
  2. Go stand within 50 feet of the powered message display.
  3. Open the Nevco ONE Controller App and expand the navigation menu. Then select the Devices option. You will notice an entry for the display device's serial number if previously connected otherwise tap the add (+) icon and select the display device from the list.
  1. Tap the edit icon to open the display device details. Once the device detail page is loaded the MAC address can be found on the Status tab.
  1. To setup a static IP address on the Settings tab expand the Advanced Settings section. Scroll up to the IP Networks/Ethernet section and select the Static IP enabled slider to activate. Then enter the appropriate networking configuration info.

The figure below labels the connections made by the installer from A – K. The chart below lists the problem that can be identified should each connection be faulty. Should a problem arise on any one component, consult the trouble shooting guide specific to that device.

NOTE
NOTE: All connections inside the Message Center have been made at the NEVCO Factory. Each Message Center requires an Ethernet connection to the local Network. Each Message Center also requires Power (see Table 1).
NOTE
NOTE: For double sided and/or double cabinet message centers. The input signal for subsequent cabinets comes from the output of the previous cabinet. A separate power circuit is required for each cabinet.
SituationSymptomConnectionSolution
The message Center is not displaying a messageThe fans on ALL power supplies are runningF,BEnsure POE is powered on and cables are connected
The fans on ALL power supplies are runningGEnsure an Ethernet straight through cable has been used, is making a good connection at both ends.
The fans on ALL power supplies are NOT runningJCheck Power Switch on disconnect box inside message center
JCheck connections in disconnect box (power hookup)
JCheck branch circuit; was there a photocell on an existing sign install?
On a double sided Message Center, One side is displaying the message, the other is notK,IEnsure an Ethernet straight through cable has been used, is making a good connection at both ends.
I cannot communicate with the message centerNo Red Power LED lit on Wireless Bridge POE.ECheck branch circuit and power at the receptacle. Adapter has LED indicator
No Red Power LED lit on Wireless Access Point POE.BCheck branch circuit and power at the receptacle. Adapter has LED indicator
Message Center does not have network (See Display Install Verification section)AEnsure Switch is turned on and working properly
A,CEnsure an Ethernet straight through cable has been used and is making a good connection at both ends.
User's manual with wireless equipment explains how to measure the wireless signal strengthDReorient the wireless device's antennas to eliminate obstructions between them
Light Sensor does NOT workNot installedHInstall sensor in message center
Not enabledHMake sure the light sensor is set to auto in V3Pro
NOTE
If the problem persists please contact the Nevco Service Department. 800-851-4040

A hardware device that allows wireless communication devices to connect to a network.

Can also be configured as a

A hardware device used to connect two or more network segments.

Distributes the data inside the Message Center.

A group of pixels. Several Display Panels are combined to form the message center.

Power Over Ethernet. Used to inject power for use by a device connected to the Ethernet cable.

Converts the line voltage to 12 volts or 5 volts.

Disconnects power to a portion of the message center components. Cabinet may contain more than one.

Flat 16 conductor cable used to carry the data from the SCAN card to the display panels and from display panel to display panel.

Distributes the message center data to the SCAN card(s).

Stores, processes, and distributes the message center data to the V3SS.


After installation of the display it can be powered on and checked for networking connectivity. The Nevco ONE Player device that drives the display will cycle through diagnostic information and output it to the display. This will remain on the display until it has internet connectivity and the end user has completed setup in their Nevco ONE online account.

After initial boot up sequence which may briefly display images and, or all white sections, Information similar to the diagnostic example should begin. The actual output may vary slightly and depending on the size of the display not all lines may be visible at once and will cycle through several lines at a time. The important lines to observe are:

  • Ethernet: - This indicates if the device has connected to a local area network (LAN) and will display the device's [IP address/IP Mask] and the [Gateway IP address]. If a network was not detected it will show "No IP". The default networking client configuration of the Player is for it to expect to be assigned an IP address via DHCP.
  • Cloud Connect: - If the device has internet connectivity it will show "one.nevco.com", otherwise it will show "NO"

If the Cloud Connect status is good then networking installation to the device is complete and validated. If device has an IP address but is not cloud connected then there likely is additional network configuration to be performed on the customers network.

Test Player #123456
Playlists: 0
Display: 1920x1080 - HDTV
08:19:22 GMT-0500 (Central Daylight Time)
Software: Ver: 2.1.13 Act valid Pri
Ethernet: 192.168.1.5/24 192.168.1.1
Cloud Connect: one.nevco.com
Org: 4ca83c1d-79a3-48fa-81da-5a5224f7b292
Org Authorized: NO
Resource Sync: 0/13

Figure 2- Display Diagnostic Example


NOTE
Important. Read before installation. This is not an engineered drawing. It is intended for representation purposes only. The dimensions called out on this drawing are intended to be used as a guide only, and are not intended to be suitable for all conditions. Information specific to the message center, such as assembly instructions and electrical connections, may be found in the installation manual for that message center. Nevco recommends that you consult a professional engineer or architect familiar with the area before attempting installation. They can verify that the selected mounting beams or posts along with the brackets, screws, and other hardware items provided by you or Nevco are adequate for your local conditions. If procedures are used that are not covered in this drawing, careful analysis of the installation is urged.

Notes:

  1. Refer to sheet 3 for cabinet weights and dimensions.
PixelCabinetWeight (lbs)Suggested Column Separation2"x3"x3/16" Angle Length
20mm3' x 8'19072" to 120"7'-6"
3' x 10'24596" to 168"9'-6"
3' x 12'305120" to 168"11'-6"
3' x 16' Left18692" to 186"15'-6"
3' x 16' Right21792" to 186"15'-6"
4' x 8'23872" to 120"7'-6"
4' x 10'31796" to 144"9'-6"
4' x 12' Left186120" to 144"11'-6"
4' x 12' Right220120" to 144"11'-6"
4' x 16' Left256168" to 192"15'-6"
4' x 16' Right280168" to 192"15'-6"
16mm3' x 8'17236" to 90"7'-6"
3' x 10'20836" to 114"9'-6"
3' x 12'25852" to 138"11'-6"
3' x 16' Left16292" to 186"15'-6"
3' x 16' Right18192" to 186"15'-6"
4' x 8'22536" to 90"7'-6"
4' x 10'27336" to 114"9'-6"
4' x 12' Left19452" to 138"11'-6"
4' x 12' Right15852" to 138"11'-6"
4' x 16' Left21492" to 186"15'-6"
4' x 16' Right25592" to 186"15'-6"
10mm3' x 8'20436" to 90"7'-6"
3' x 10'25536" to 114"9'-6"
3' x 12'30652" to 138"11'-6"
3' x 16' Left19492" to 186"15'-6"
3' x 16' Right21492" to 186"15'-6"
4' x 8'27236" to 90"7'-6"
4' x 10'34036" to 114"9'-6"
4' x 12' Left22252" to 138"11'-6"
4' x 12' Right18652" to 138"11'-6"
4' x 16' Left25192" to 186"15'-6"
4' x 16' Right29392" to 186"15'-6"

Notes:

  1. Bracket orientation labels are found on back of message center
  2. 3/8" bolts to attach brackets to message center are provided by Nevco
PixelSizeLeft/Right CabinetDim (A)Dim (B)Dim (C)Dim (D)
20mm3 x 836 1/831 5/812
20mm3 x 1036 1/831 5/812
20mm3 x 1236 1/831 5/812
20mm3 x 16L36 1/831 5/812102 1/4
20mm3 x 16R36 1/831 5/812102 1/4
20mm4 x 848 1/843 5/812
20mm4 x 1048 1/843 5/812
20mm4 x 12L48 1/843 5/81278 1/4
20mm4 x 12R48 1/843 5/81278 1/4
20mm4 x 16L48 1/843 5/812102 1/4
20mm4 x 16R48 1/843 5/812102 1/4
16mm3 x 836 1/831 5/812
16mm3 x 1036 1/831 5/812
16mm3 x 1236 1/831 5/812
16mm3 x 16L36 1/831 5/812106
16mm3 x 16R36 1/831 5/812106
16mm4 x 848 1/843 5/812
16mm4 x 1048 1/843 5/812
16mm4 x 12L48 1/843 5/81282 1/16
16mm4 x 12R48 1/843 5/81282 1/16
16mm4 x 16L48 1/843 5/812106
16mm4 x 16R48 1/843 5/812106
10mm3 x 836 1/831 5/812
10mm3 x 1036 1/831 5/812
10mm3 x 1236 1/831 5/812
10mm3 x 16L36 1/831 5/812102 1/4
10mm3 x 16R36 1/831 5/812102 1/4
10mm4 x 848 1/843 5/812
10mm4 x 1048 1/843 5/812
10mm4 x 12L48 1/843 5/81278 1/4
10mm4 x 12R48 1/843 5/81278 1/4
10mm4 x 16L48 1/843 5/812102 1/4
10mm4 x 16R48 1/843 5/812102 1/4

NOTE
Important. Read before installation. This is not an engineered drawing. It is intended for representation purposes only. The dimensions called out on this drawing are intended to be used as a guide only, and are not intended to be suitable for all conditions. Information specific to the message center, such as assembly instructions and electrical connections, may be found in the installation manual for that message center. Nevco recommends that you consult a professional engineer or architect familiar with the area before attempting installation. They can verify that the selected mounting beams or posts along with the brackets, screws, and other hardware items provided by you or Nevco are adequate for your local soil conditions, wind loads and other conditions. If procedures are used that are not covered in this drawing, careful analysis of the installation is urged.
NOTE
Important: Bracing (angle, tubing, etc.) must fully support message center. Nevco recommends that you consult a local professional architect or engineer to verify the framework the cabinet will be mounted to.

Upper and Lower Laterals should be placed 2¼" from the top and bottom of the message center as shown.

Check Electrical Prints to determine conduit requirements. (Must meet electric codes.)

Coarse aggregate concrete — Minimum 24" diameter, Minimum 5' deep.

PixelCabinetWeight (lbs)0-5 ft. Off Ground Suggested Column6-10 ft. Off Ground Suggested ColumnSuggested Lateral Size
20mm3' x 8'190W8x13W8x13HSS3x2.5 x .125
3' x 10'245W8x13W10x19HSS3x2.5 x .125
3' x 12'305W8x13W10x19HSS3x2.5 x .125
3' x 16' Left186W12x14W8x21HSS3x3 x .125
3' x 16' Right217W12x14W8x21HSS3x3 x .125
4' x 8'238W8x13W10x19HSS3x2.5 x .125
4' x 10'320W8x13W10x15HSS3x2.5 x .125
4' x 12' left226W8x18W10x22HSS3x3 x .125
4' x 12' right260W8x18W10x22HSS3x3 x .125
4' x 16' left256W8x21W12x26HSS3x3 x .125
4' x 16' right280W8x21W12x26HSS3x3 x .125
16mm3' x 8'190W8x13W10x19HSS3x2.5 x .125
3' x 10'229W8x13W10x19HSS3x2.5 x .125
3' x 12'284W8x13W10x19HSS3x2.5 x .125
3' x 16' Left173W12x14W8x21HSS3x3 x .125
3' x 16' Right205W12x14W8x21HSS3x3 x .125
4' x 8'248W8x13W10x19HSS3x2.5 x .125
4' x 10'300W8x13W10x15HSS3x2.5 x .125
4' x 12' Left194W8x18W10x22HSS3x3 x .125
4' x 12' Right193W8x18W10x22HSS3x3 x .125
4' x 16' Left231W8x21W12x26HSS3x3 x .125
4' x 16' Right285W8x21W12x26HSS3x3 x .125
10mm3' x 8'204W8x13W10x19HSS3x2.5 x .125
3' x 10'255W8x13W10x19HSS3x2.5 x .125
3' x 12'306W8x13W10x19HSS3x2.5 x .125
3' x 16' Left194W12x14W8x21HSS3x3 x .125
3' x 16' Right214W12x14W8x21HSS3x3 x .125
4' x 8'272W8x13W10x19HSS3x2.5 x .125
4' x 10'340W8x13W10x15HSS3x2.5 x .125
4' x 12' Left222W8x18W10x22HSS3x3 x .125
4' x 12' Right186W8x18W10x22HSS3x3 x .125
4' x 16' Left251W8x21W12x26HSS3x3 x .125
4' x 16' Right293W8x21W12x26HSS3x3 x .125

Notes:

  1. Bracket orientation labels are found on back of message center
  2. 3/8" bolts to attach brackets to message center are provided by Nevco
PixelSizeLeft/Right CabinetDim (A)Dim (B)Dim (C)Dim (D)
20mm3 x 836 1/831 5/812
20mm3 x 1036 1/831 5/812
20mm3 x 1236 1/831 5/812
20mm3 x 16L36 1/831 5/812102 1/4
20mm3 x 16R36 1/831 5/812102 1/4
20mm4 x 848 1/843 5/812
20mm4 x 1048 1/843 5/812
20mm4 x 12L48 1/843 5/81278 1/4
20mm4 x 12R48 1/843 5/81278 1/4
20mm4 x 16L48 1/843 5/812102 1/4
20mm4 x 16R48 1/843 5/812102 1/4
16mm3 x 836 1/831 5/812
16mm3 x 1036 1/831 5/812
16mm3 x 1236 1/831 5/812
16mm3 x 16L36 1/831 5/812106
16mm3 x 16R36 1/831 5/812106
16mm4 x 848 1/843 5/812
16mm4 x 1048 1/843 5/812
16mm4 x 12L48 1/843 5/81282 1/16
16mm4 x 12R48 1/843 5/81282 1/16
16mm4 x 16L48 1/843 5/812106
16mm4 x 16R48 1/843 5/812106
10mm3 x 836 1/831 5/812
10mm3 x 1036 1/831 5/812
10mm3 x 1236 1/831 5/812
10mm3 x 16L36 1/831 5/812102 1/4
10mm3 x 16R36 1/831 5/812102 1/4
10mm4 x 848 1/843 5/812
10mm4 x 1048 1/843 5/812
10mm4 x 12L48 1/843 5/81278 1/4
10mm4 x 12R48 1/843 5/81278 1/4
10mm4 x 16L48 1/843 5/812102 1/4
10mm4 x 16R48 1/843 5/812102 1/4
NOTE
\Note:** The installation methods shown above may require the relocation of power/signal panels.
  • Cabinets designed to join end to end.
  • Make sure panels of joining cabinets line up horizontally and that both cabinets are level. See note 1.
  • If installing message center on laterals, shimming techniques can be utilized to align and level the two cabinets.
  • Install one cabinet at a time.
  • Make sure panels of joining cabinets line up horizontally and that both cabinets are level.

NOTE
Important. Read before installation. Power entrances are located on access panels with 2x4 box. The location of this panel may vary between different message centers. Access panels can be swapped to allow placement of incoming power/signal on the side, back or bottom of the message center typically. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. All personnel who work with electrical connections must be educated in the safe procedures for installing and repairing electrical connections before they are given the responsibility of performing such tasks. Conduit and fittings are supplied by installer.
  • Black = Line
  • White = Neutral
  • Green = Ground
  • Wirenuts Provided
  • Grounded pigtail located inside 2x4 box. Must connect when connecting power.

\* National Electric code requires a disconnect switch within sight of the sign or lockable within the building. If neither is available, install a disconnect at the sign.

NOTE
NOTE: It is not necessary to remove message center display panels to make any of the above connections.
  • Power/Signal-In panel can be relocated to side, bottom or back of message centers for wall mounts or adjacent signs.
  • Feed panel through hole as shown to change location of access panels.
NOTE
NOTE: This Raintight box only applies to installations greater than 325 ft.

Notes:

  1. Connect same color fiber optic cable to "TX" in the control room that is connected to "RX" at the outdoor junction box. Connect same color fiber optic cable to "RX" in the control room that is connected to "TX" at the outdoor junction box. Only attempt termination of fiber optic connections if properly trained and qualified.
  2. The rain-tight box and components shown above are required at the display and in the control room. Make connections as shown both sides.

ETHERNET CABLE

  • Display Side: 25' Signal-In on message center.
  • Control Room Side: 3' to Composer PC
  • 12V AC/DC adaptor to Media Converter
  • Incoming Fiber Optic Signal
  • Incoming Power
  • Box, outlet and cover supplied by Nevco
  • Conduit fittings supplied by others. Use only rain-tight fittings.
  • Media Converter Harness
  • SFP TO LC FIBER ADAPTER

\* Media Converter (mount on back of raintight box)

Mounting Media Converter:

  1. Install media converter using two 2" pieces of velcro-type fastener provided by Nevco.
  2. Peal adhesive backing and place a strip on back of raintight box and a strip on the media converter. Press firmly to attach.
NOTE
Important. Read before installation. Power entrances are located on access panels with 2x4 box. The location of this panel may vary between different message centers. Access panels can be swapped to allow placement of incoming power/signal on the side, back or bottom of the message center typically. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. All personnel who work with electrical connections must be educated in the safe procedures for installing and repairing electrical connections before they are given the responsibility of performing such tasks. Conduit and fittings are supplied by installer.

Notes:

  • Cabinet to cabinet signal connections are straight through ethernet.
  • Cabinet 1 is identified by Nevco logo next to Power/Signal-In panel.
  • Remove knockouts in access panels where necessary to make connections.
  • Temperature Sensor/Photo Cell
  • Power
  • Power/Signal-In Panel
  • Signal Out (remove plug or knockout to make connection)
  • For double sided message centers, connect cable here and run straight through to Signal-In of second message center.
  • Connect ethernet from Signal-Out of first cabinet straight through to Signal-In of second cabinet.
  • Remove panel and re-mount according to label with 2x4 box on outside of cabinet.
  • Signal-Out
  • Power
  • Power/Signal-In Panel
Message Center A                         Message Center B
Signal Out | Signal In | Signal Out      Signal In
Power                  Power, Signal-In
                       (ethernet connection from media converter)
Child Right            Parent Left
Child Left             Child Right
Power, Signal In
Signal In
Signal Out             Power
                       Signal Out

NOTE
Important. Read before installation. Power entrances are located on access panels with 2x4 box. The location of this panel may vary between different message centers. Access panels can be swapped to allow placement of incoming power/signal on the side, back or bottom of the message center typically. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. All personnel who work with electrical connections must be educated in the safe procedures for installing and repairing electrical connections before they are given the responsibility of performing such tasks. Conduit and fittings are supplied by installer.
  • Black = Line
  • White = Neutral
  • Green = Ground
  • Wirenuts Provided
  • Grounded pigtail located inside 2x4 box. Must connect when connecting power.

\* National Electric code requires a disconnect switch within sight of the sign or lockable within the building. If neither is available, install a disconnect at the sign.

NOTE
NOTE: It is not necessary to remove message center display panels to make any connections.
NOTE
NOTE: For indoor installations, a raintight box is not required. Make connections same as above.
  • Power/Signal-In panel can be relocated to side, bottom or back of message centers for wall mount or adjacent signs.
  • Feed panel through hole as shown to change location of access panels.
  • Make connections by removing other access panel near Power/Signal-In panel. Replace all covers when connections have been made.

Signal Strength Meter — 3 bars required for adequate signal. Point client bridge at access point in control room to obtain required signal strength.

Client Bridge — Mount in Clear-Line-Of-Sight to wireless transmitter.

  • Ethernet Cable (straight through from receiver to POE)
  • Ethernet Signal to Power/Signal-In Access Panel
  • Raintight Box (See Sheet 2)
  • Power to Raintight Box
  • Power from Branch Circuit
  • Sign Power to 2x4 Box (consult installation instructions for amperage requirement)
  • Disconnect Switch
NOTE
NOTE: This Raintight box only applies to installations using wireless connectivity.

Notes:

  1. Use raintight fittings.
  2. Indoor installations do not require a rain-tight box. Make connections same as above.

Inside Raintight Box (Door Removed for Clarity)

Power Over Ethernet Supply (POE)

Mounting POE:

  1. Cut supplied adhesive-backed fastening material into (2) 2" pieces.
  2. Peal backing off of one piece and place on back of raintight box in desired location.
  3. Place second piece on back of POE.
  4. Press POE firmly onto back of raintight box.
  • Water-tight bushing supplied by Nevco (for ethernet cable to wireless receiver)
  • 25' Ethernet from "POE" to wireless receiver (supplied by Nevco)
  • Incoming Power
  • 25' ethernet from "LAN" to message center SIGNAL-IN.
  • Signal to message center
  • Power adapter supplied by Nevco.
  • Water-tight fittings required (supplied by others)
  • Box, outlet and cover supplied by Nevco.
  • Ethernet: Wireless Receiver
  • Ethernet: Message Center Signal
NOTE
Important. Read before installation. Power entrances are located on access panels with 2x4 box. The location of this panel may vary between different message centers. Access panels can be swapped to allow placement of incoming power/signal on the side, back or bottom of the message center typically. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. All personnel who work with electrical connections must be educated in the safe procedures for installing and repairing electrical connections before they are given the responsibility of performing such tasks. Conduit and fittings are supplied by installer.

Notes:

  • Cabinet to cabinet signal connections are straight through ethernet.
  • Cabinet 1 is identified by Nevco logo next to Power/Signal-In panel.
  • Remove knockouts in access panels where necessary to make connections.
  • Temperature Sensor/Photo Cell
  • Power
  • Power/Signal-In Panel
  • Signal Out (remove plug or knockout to make connection)
  • For double sided message centers, connect cable here and run straight through to Signal-In of second message center.
  • Connect ethernet from Signal-Out of first cabinet straight through to Signal-In of second cabinet.
  • Remove panel and re-mount according to label with 2x4 box on outside of cabinet.
  • Signal-Out
  • Power
  • Power/Signal-In Panel
Message Center A                         Message Center B
Signal Out | Signal In | Signal Out      Signal In
Power                  Power, Signal-In
                       (ethernet connection from media converter)
Child Right            Parent Left
Child Left             Child Right
Power, Signal In
Signal In
Signal Out             Power
                       Signal Out
NOTE
Important: Wireless devices should be in Clear Line of Sight from each other. Penetration of obstacles by the wireless signal is dependent on the material of the obstacle as well as the overall distance between devices. Both units are suitable for outdoor installation. If building walls become a problem, mount the access point outside the building.
  • Access Point — Remove cover and plug into ethernet port closest to the center of the access point.
  • 3' Ethernet (from Access Point to Ethernet Switch)
  • 25' ethernet (from POE LAN port to Access Point)
  • Power Over Ethernet (POE) Supply
  • LAN port on POE
  • Client Bridge
  • Ethernet Switch (Provided by Customer)
  • Fasten client bridge to mounting bracket using 2 supplied zip-ties.
  • Run zip-ties through two holes in bracket and through slot on client bridge.
  • Client bridge can be mounted to bracket at various angles to achieve optimum line of sight to access point in control room.
  • Bolt or clamp bracket to column or other structure. (hardware supplied by others)

  1. Place in a discrete location.
  2. Do not completely enclose the sensor.
  3. Placing the sensor in direct sunlight can elevate the temperature readings.
  4. Automatically adjusts brightness from 7000-960 NITS.
  5. The software that runs the display will allow the operator to set brightness as well as the display frame speed etc. to meet local ordinances.

Connect cable from sensor to Sensor Port of V3SS located inside either the message center or a rain tight box. If V3SS is located in rain tight box, drill hole in rain tight box and run cable through. Install raintight fitting.

Sensor can be screwed directly to the side of the cabinet using the attached angle bracket.

\* Connections can be made using supplied bushings and nuts or 1/2 conduit.

  • \ Power/Signal-In Access Panel** — Remove other access panel to make connections and replace when finished. Wires for connections located inside cabinet.
  • Power
  • Signal-In
  • cross over from media converter
  • remove knockout label 'Signal In' on panel to make connection